The air o cell sampler is designed to operate at an optimal flow rate of 15 liters per minute lpm.
Air o cell sampling procedure.
Air o cell iaq sampling cassettes.
The zefon air o cell is an impaction based air sampler used in microbial sampling procedures designed to pull air across a tacky sampling medium trapping any airborne particulates.
It is also capable of operating in any vertical or horizontal orientation or.
Calibrated pump and timer air o cell cassettes permanent marker.
The user can employ any sampling pump capable of a minimum fl ow rate of 15 lpm.
Remove the seal from the top of the cassette and retain to reseal when sampling is complete.
It is designed for use in conjunction with a high flow vacuum pump set to 15 lpm liters per minute.
The air o celltm air sampling cassette is a sampling device designed for the rapid collection and analysis of a wide range of airborne aerosols.
These include fungal spores pollen insect parts skin cell fragments fibers and inorganic particulates.
The air flow path through the air o cell cassette is illustrated below in figure 1.
The first choice of air quality professionals air o cell sampling cassettes provide a quick method of collecting particles from the air that can be tested for a wide range of viable and non viable aero allergens including pollen.
2 remove and retain tape seal covering air o cell inlet and outlet.
Sampling procedure 1 prior to sampling calibrate the pump to 15 liters per minute.
The air flow path through the air o cell cassette is illustrated in figure 1.
3 attach the outlet round hole to the supplied tubing adapter available upon request or use standard pvc tubing for use with high volume pumps only.
Please refer to the user manual of the cassette and or pump for a complete list of instructions.
The user can employ any sampling pump capable of a minimum flow rate of 15 lpm.
Check the expiry date of the air o cell is current and remove the seal from the bottom of the cassette and retain to reseal when sampling is complete.
Recommended sampling procedures general.
Comprehensive expertise in laboratory testing field sampling design research and development failure analysis and can routinely provide expert witness support.
Attach the cassette to a calibrated bio pump.
The air o cell product line contains some of our bestselling products.
Microbiology sampling protocol for use with air o cell cassettes this is a general list of procedures to follow in order to ensure quality and accuracy of analysis.
The air o cell sampler is designed to operate at an optimal flow rate of 15 liters per minute.
Air enters the cassette the particles become impacted on the sampling substrate and the air.
Recommended sampling procedures general.
The air o cell sampler is designed to operate at an optimal fl ow rate of 15 liters per minute.
Recommended sampling procedures general.